Navin's HARMONY TOWERS
 
Front Elevation
Location
Flats Details
Site Plans
Specifications
Features

Payment Schedule

Project Status
Click to download E-Brochure
Permit Number from CMDA or DTCP - C/PP/MSB.IT/38 A to F 2006 Dt: 15.10.2008

Proposed Sofware / IT building. Date of completion December  2009. For outright Sale/Lease.

Click here to enlarge
 
 
Locations:
Click here to enlarge

Address:
Address : # 107& 108, Harris Road, (erstwhile Chitra Talkies),
1,2,3,4 Langs Garden Road, Mount Road, Chennai - 600 002 .

Top

Flat Area:
Block/Floors
Saleable
Common Area Plinth Area Corpet Area Wall Area
One Floor Area 8440 1247 7193 6900 293
 
Floor Plates Available:
Floor Area in sqft / Plates
VI 8440
VII 8440
VIII 8440
IX 8440
X 8440
 
Project Plans:
Basement Floor Plan:
Click here to Enlarge
 
Click here to Enlarge
 
Site Map

 
Specifications
 

1.

RCC  Framed Structure on Pile Foundations

2.

Designed for Seismic  Zone 1 1 1 – safe against earthquakes

3.

Post Tensioned  Flat  Slabs – No beams and hence large floor clearances

4.

10 meter  clear column Grids with large column free spaces

5.

Individual  Floor Height – 3300mm roof slab to roof slab

6.

Large Areas of Glass Facades – Imposing  Elevation

7.

Granite / Marble / Vitrified Tile Flooring in Lobbies and  Staircases

8.

Granite / Marble Cladding for lift facia in lobbies

9.

Vitrified / Ceramic Tile Flooring and  7 feet high Dadoing in Toilets

10.

Painting in Emulsion over Putty in Common Areas

 
Features
 

Plumbing / Sanitary

:
  • Water  requirements  designed  @ 45 liters per day per head
  • Parry ware / Hindustan White Sanitary Ware
  • Jaguar  Chronium Plated Continental Range Fittings
  • Separate Toilet  for Physically Challenged
  • Sewage Treatment Plant – for use of recycled water for flushing / gardening

Fire Fighting 

:
  • Modern Automatic System  strictly conforming to NBC 2005
  • Full Fledged  Hydrant System – Wet Risers to cover entire floor of the Building
  • First Aid Hose Reel,Landing  Valves / CP Hoses at each  floor
  • Ring  Main around the building with additional Fire Brigade inlets for external                         source of fire protection
  • 100% Backup Pumping Units on alternate power source with motor control                           and center panels and individual panels for diesel and jockey pumps
  • Automatic Sprinkler System for ground / Stilt floor with Dedicated Pumping Units                and with 100% backup
  • Early warning microprocessor Detection System with individual control panel with     imported Edwards system panel

Air Conditioning

:
  • Full Air Conditioned Office Space  - Total Calculated Load : 352TR. – 44 Ton for 1st  & 10th floors each &33 Ton per floor for 2nd to 9th  floors
  • Designed  for Inside  Ambient  Temperature of 24 degrees (plus or minus 2 degrees) Celsius by industry  average.
  • Air  Conditioning distribution upto AHUs only. Distribution  into office areas from AHU Rooms,Ducting,Branching,Diffusers etc.are under client’s scope
  • Dedicaated  earth pits is under client’s scope

Electrical Lighting

:
  • Design  connected lighting load of 10KW per floor.Design lighting level – 300 LUX.
  • Designed for  LT power supply  & provision given for upgrading to HT supply if block booking of at least five floors is made by a single client.
  • Distribution cable from EB room to individual plate provided.All internal office cabling & switches are under client’s scope.
  • Only shaft provision given.Distribution / Cabling are under client’s Scope.

UPS

:
  • Centralized  Location of UPS possible for each floor plate.
  • UPS shaft provided.
  • Total Load includes provision for ups for Data Room.

Common Service

:
  • Common  Area  lighting, Car Park lighting, lifts,water & fire fighting pumps,ETP, STP etc. provided
  • Sufficient  capacitor for APFC power  factor compensation for the reactive loads provided.Any extra compensation required at each floor level is not covered.

EB Supply

:
  • The total connected load: 1500 KVA approx.(excluding common area)
  • Active load: 1050 KVA approx (@75 KVA per floor plate)
  • Transformer capacity: 1250 KVA approx + 200 KVA for Common Area

DG  for 100% Back up:

:
  • 100% backup including for air conditioning.
  • Capacity : 1No – 1010 KVA + 200 KVA for Common Area

Lifts

:
  • 3nos.Automated High speed Lifts of premium make

 
SCHEDULE OF PAYMENTS
 
50% Advance at the time of booking
25% upon completion of Shell frame
20% upon completion of structure & Plastering
5% before handing over.
 
PROJECT STATUS
 
Harmony Tower
:
7th Floor Roof Slab Completed
     
CLICK HERE TO DOWNLOAD 885KB